D1213A-01T
Document number: DS35762 Rev. 5 - 2
2 of 4
www.diodes.com
November 2012
© Diodes Incorporated
D1213
-01T
NEW PRODUCT
Maximum Ratings (@T
A
= +25°C, unless otherwise specified.)
Characteristic Symbol Value Unit Conditions
Peak Pulse Current
I
PP
5 A
8/20μs, Per Figure 3
ESD Protection – Contact Discharge
V
ESD
Contac
±8 kV
Standard IEC 61000-4-2
ESD Protection – Air Discharge
V
ESD
Ai
±15 kV
Standard IEC 61000-4-2
Thermal Characteristics
Characteristic Symbol Value Unit
Package Power Dissipation (Note 6)
P
D
250 mW
Thermal Resistance, Junction to Ambient (Note 6)
R
JA
500
°C/W
Operating and Storage Temperature Range
T
J
, T
STG
-65 to +150
°C
Electrical Characteristics (@T
A
= +25°C, unless otherwise specified.)
Characteristic Symbol Min Typ Max Unit Test Conditions
Reverse working voltage VRWM — - 3.3 V —
Reverse current (Note 7)
I
R
—
0.1 1.0 μA
V
R
= V
RWM
= 3.3V
Reverse breakdown voltage VBR 6.0
— —
V
I
R
= 1mA
Forward voltage
V
F
0.6 0.8 0.95 V
I
F
= 8mA
Reverse clamping voltage, Positive Transients
V
CL1
—
10.0
—
V
I
PP
= 1A, t
= 8/20μs
Reverse clamping voltage, Negative Transients
V
CL2
—
-1.7
—
V
I
PP
= -1A, t
= 8/20μs
Dynamic resistance
R
DYN
—
0.9
—
Ω
I
R
= 1A, t
= 8/20μs
Capacitance
C
T
—
0.85 1.2 pF
V
R
= 1.65V, f = 1MHz
Notes: 6. Device mounted on FR-4 PCB pad layout (2oz copper) as shown on Diodes, Inc. suggested pad layout AP02001, which can be found on our website at
http://www.diodes.com.
7. Short duration pulse test used to minimize self-heating effect.
8. For information on the impact of Diodes' USB 2.0 compatible ESD protectors on signal integrity including eye diagram plots, please refer to AN77 at the
following URL: http://www.diodes.com/destools/appnote_dnote.html.
0125175
150
50
100
0
T , AMBIENT TEMPERATURE ( C)
Figure 1 Power Derating Curve
A
°
,
WE
DISSI
A
I
N (mW)
D
25 10050 75 150
25
75
125
300
175
Note 6
200
225
250
275
0
50
25 50
75 100 125
150
EAK
LSE DE
A
I
%
PEAK POWER OR CURRENT
T , AMBIENT TEMPERATURE (°C)
Figure 2 Pulse Derating Curve
A
0
100
25
75
175 200
Commentaires sur ces manuels