AH276Q
Document number: DS31066 Rev. 6 - 2
3 of 6
www.diodes.com
September 2013
© Diodes Incorporated
H276Q
Recommended Operating Conditions (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter Conditions Min Max Unit
V
CC
Supply Voltage (Note 4) Operating 3.5 20 V
T
A
Operating Ambient Temperature Operating -20 +85
C
Note: 4. The output DO/DOB is switching as magnetic field change (S>300G, N<-300G).
Electrical Characteristics (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter Conditions Min Typ Max Unit
V
Z
Output Zener Breakdown — 35 — V
V
CE(SAT)
Output Saturation Voltage
V
CC
= 14V, I
L
= 400mA
—
0.6 0.9 V
I
CEX
Output Leakage Current
V
CE
= 14V, V
CC
= 14V
—
<0.1 10 µA
I
CC
Supply Current
V
CC
= 20V, Output Open
7 16 25 mA
Magnetic Characteristics (Note 5) (@T
A
= +25°C, V
CC
= 14V, unless otherwise specified.)
A grade
Symbol Characteristic Min Typ Max Unit
Bop Operate Point 10 — 50 Gauss
Brp Release Point -50 — -10 Gauss
Bhy Hysteresis — 75 — Gauss
B grade
Symbol Characteristic Min Typ Max Unit
Bop Operate Point 5 — 70 Gauss
Brp Release Point -70 — -5 Gauss
Bhy Hysteresis — 75 — Gauss
C grade
Symbol Characteristic Min Typ Max Unit
Bop Operate Point — — 100 Gauss
Brp Release Point -100 — — Gauss
Bhy Hysteresis — 75 — Gauss
Note: 5. Magnetic characteristics are for design information, which will vary with supply voltage, operating temperature and after soldering.
Bhy
Vsat
Vcc
( Output Voltage )
Brp Bop
0
S
N
( Magnetic flux density B )
DO
Turn on
Turn off
( off-state )
( on-state )
Bhy
Vsat
Vcc
( Output Voltage )
Brp Bop
0
S
N
( Magnetic flux density B )
DOB
Turn oFF
Turn on
( off-state )
( on-state )