Diodes AH1801 Manuel d'utilisateur Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 10
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
AH1801
MICROPOWER, ULTRA-SENSITIVE HALL EFFECT
SWITCH
AH1801 Rev. 7 6 of 10 FEBRUARY 2009
www.diodes.com © Diodes Incorporated
Magnetic Characteristics (T
A
= 25°C, Vdd = 3V)
(1mT=10 Gauss)
Symbol Characteristic Min Typ Max Unit
Bops(south pole to brand side)
Operate Point
- 40 60
Gauss
Bopn(north pole to brand side) -60 -40 -
Brps(south pole to brand side)
Release Point
10 30 -
Brpn(north pole to brand side) - -30 -10
Bhy( BrpxBopx )
Hysteresis - 10 -
Notes: 6. Typical data is at T
A
=25 °C, Vdd=3V, and for design information only.
7. Operate point and release point will vary with supply voltage and operating temperature.
Output ( Voltage )
B
opn
Brpn
Turn
on
Turn off
( off-state )
( on-state )
Brps Bops
Magnetic
Turn off
Turn
on
-B
+B
(1) SC59 / DFN2020-3 /DFN2020-6
T
A
(°C)
25 50 60 70 80 85 90 100 110 120 130 140 150
P
D
(mW)
230 184 166 147 129 120 110 92 74 55 37 18 0
Power Dissipation Curve
0
100
200
300
0 25 50 75 100 125 150
T
A
(
C)
P
D
(mW)
85